4F0910401N 4F0910401N_0030 Bosch EDC16CP34 map pack – Audi A6 3.0 TDI V6 224hp
4F0910401NSW0030CAL4F0910401N_0030This pack holds 192 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
Audi A6 3.0 TDI V6 224hp · Bosch EDC16CP34
Also written: 4F0 910 401 N · 4F0-910-401-N
More packs: Audi A6 · Bosch EDC16CP34
All 192 maps
The percentage beside a name: the share of the 135 Bosch EDC16CP34 packs that name it too.
Injection System 65 maps
- Fuel quantity injected f(RPM,Trq)9 maps · 99%
- Smoke limitation - Lower Lambda value6 maps · 97%
- Injection time77%
- Injection timing - Main Injection Base Map 140 maps · 64%
- Fuel quantity limiter61%
- Injection correction6 maps · 39%
- Injection correction f(ECT)2 maps · 38%
Turbo System 39 maps
- Turbo pressure16 maps · 100%
- Limiter of Turbo pressure f(APS)2 maps · 99%
- Variable Geometry Duty Cycle20 maps · 84%
- Limiter of Turbo pressure43%
Rail 29 maps
- Rail pressure12 maps · 99%
- Rail pressure limiter f(RPM,Fuel_Q)2 maps · 99%
- Rail pressure limiter f(RPM,Fuel_T)2 maps · 84%
- Rail pressure limiter13 maps · 37%
Engine Torque 27 maps
- Limiter of Maximum torque f(APS)4 maps · 99%
- Maximum torque for fifth gear94%
- Maximum torque for first gear94%
- Maximum torque for forth gear94%
- Maximum torque for second gear94%
- Maximum torque for third gear94%
- Maximum torque for sixth gear93%
- Torque during cranking f(RPM,ECT)2 maps · 73%
- Maximum torque during shift gear2 maps · 56%
- Torque request during take off condition - First Gear2 maps · 53%
- Torque request during take off condition - Automatic Transmission50%
- Torque request during take off condition - Second Gear4 maps · 50%
- Torque request during take off condition - Forth Gear48%
- Torque request during take off condition - Third Gear48%
- Limiter of Maximum torque4 maps · 45%
Air Control 26 maps
- Air quantity - Base map20 maps · 76%
- EGR control - Opening percentage6 maps · 50%
Limiters 5 maps
- Maximum speed of vehicle4 maps · 54%
- Idle engine speed f(ECT)44%
Deactivations 1 map
- Speed limiters (switch)30%
How this pack differs from other Bosch EDC16CP34 packs
Named here, but by under half of the 135 Bosch EDC16CP34 packs:
- Speed limiters (switch) 30%
- Rail pressure limiter 37%
- Injection correction f(ECT) 38%
- Injection correction 39%
- Limiter of Turbo pressure 43%
- Idle engine speed f(ECT) 44%
- Limiter of Maximum torque 45%
- Torque request during take off condition - Forth Gear 48%
- Torque request during take off condition - Third Gear 48%
- EGR control - Opening percentage 50%
Named by at least half of them, but not by this pack:
- Torque request during take off condition 73%
- Maximum torque for reverse gear 64%
- Torque request during standard condition 50%
192 maps against the Bosch EDC16CP34 median
The 135 Bosch EDC16CP34 packs name 27 to 193 maps, median 94; 97% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Injection System | 65 | 32 |
| Turbo System | 39 | 18 |
| Rail | 29 | 16 |
| Engine Torque | 27 | 18 |
| Air Control | 26 | 11 |
| Limiters | 5 | 4 |
| Deactivations | 1 | 0 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.