1579020700 1579037100 Bosch MED17.7.3 map pack – Mercedes S 5.5 577hp
1579020700CAL1579037100This pack holds 326 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
Mercedes S 5.5 577hp · Bosch MED17.7.3
Also written: A1579020700 · A 157 902 07 00 · A1579037100 · A 157 903 71 00
More packs: Mercedes S · Bosch MED17.7.3
All 326 maps
The percentage beside a name: the share of the 25 Bosch MED17.7.3 packs that name it too.
Engine Torque 85 maps
- Optimal engine torque3 maps · 100%
- Limiter of Maximum torque13 maps · 92%
- Calculated engine torque7 maps · 88%
- Torque monitoring55 maps · 60%
- Torque request during standard condition6 maps · 52%
- Debounce time to detect a permanent torque limit36%
Air Control 63 maps
- Airflow mass through throttle valve100%
- Requested engine load100%
- Throttle valve - operating angle100%
- Engine load limiter4 maps · 88%
- Exhaust gas temperature54 maps · 72%
- Maximum relative air charge for catalyst diagnosis48%
- Minimum relative air charge for catalyst diagnosis48%
Spark Advance 48 maps
- Spark Advance base map32 maps · 100%
- Limiter of knocking sensor8 maps · 60%
- Optimal Spark Advance8 maps · 52%
Injection System 44 maps
- Lambda for component protection18 maps · 100%
- Requested Lambda2 maps · 92%
- Injection enrichment6 maps · 68%
- Fuel quantity limiter11 maps · 48%
- Injection correction7 maps · 44%
Turbo System 33 maps
- Turbo pressure5 maps · 92%
- Limiter of Turbo pressure f(IAT)84%
- Wastegate Duty Cycle84%
- Limiter of Turbo pressure20 maps · 80%
- Maximum lower tolerance of pressure before throttle44%
- Characteristic widening error threshold due to desired boost pressure dynamics40%
- Delta pressure limit under overcharge error40%
- Deviation negative threshold of boost pressure for detecting overcharge pressure40%
- Lower limit for low pass filtered boost control deviation40%
- Ambient pressure threshold for charge pressure diagnostics36%
Deactivations 30 maps
- Lambda Sensor (1=ON, 0=OFF)30 maps · 84%
Limiters 23 maps
- RPM Limiter9 maps · 100%
- Maximum speed of vehicle11 maps · 92%
- RPM limiter (higher threshold)2 maps · 76%
- Maximum speed of vehicle A60%
How this pack differs from other Bosch MED17.7.3 packs
Named here, but by under half of the 25 Bosch MED17.7.3 packs:
- Ambient pressure threshold for charge pressure diagnostics 36%
- Debounce time to detect a permanent torque limit 36%
- Characteristic widening error threshold due to desired boost pressure dynamics 40%
- Delta pressure limit under overcharge error 40%
- Deviation negative threshold of boost pressure for detecting overcharge pressure 40%
- Lower limit for low pass filtered boost control deviation 40%
- Injection correction 44%
- Maximum lower tolerance of pressure before throttle 44%
- Fuel quantity limiter 48%
- Maximum relative air charge for catalyst diagnosis 48%
- Minimum relative air charge for catalyst diagnosis 48%
Named by at least half of them, but not by this pack:
- Optimal Spark Advance 1 60%
- Minimum Spark Advance 52%
326 maps against the Bosch MED17.7.3 median
The 25 Bosch MED17.7.3 packs name 132 to 389 maps, median 235; 88% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Engine Torque | 85 | 45 |
| Air Control | 63 | 58 |
| Spark Advance | 48 | 48 |
| Injection System | 44 | 42 |
| Turbo System | 33 | 19 |
| Deactivations | 30 | 6 |
| Limiters | 23 | 23 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.