0261S03325 1037544417 Bosch MED9.1 map pack – Volkswagen Golf 6 2.0 265hp
HW
0261S03325SW1037544417CAL1K8907115L_0020Engine Torque41Turbo System33Spark Advance29Limiters24Injection System17Air Control14Variable Valve Timing (VVT)10Rail7Deactivations6
This pack holds 181 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
Volkswagen Golf 6 2.0 265hp · Bosch MED9.1
Also written: 1 037 544 417
More packs: Volkswagen Golf 6 · Bosch MED9.1
All 181 maps
The percentage beside a name: the share of the 152 Bosch MED9.1 packs that name it too.
Engine Torque 41 maps
- Optimal engine torque2 maps · 100%
- Desired torque at wheel75%
- Calculated engine torque7 maps · 69%
- Limiter of Maximum torque56%
- Torque monitoring19 maps · 49%
- Torque limiter for clutch protection46%
- Torque request - Low speed4 maps · 43%
- Engine torque correction40%
- Torque request during standard condition3 maps · 36%
- Torque request during take off condition2 maps · 9%
Turbo System 33 maps
- Limiter of Turbo pressure2 maps · 79%
- Turbo pressure2 maps · 79%
- Limiter of impulsive turbo pressure6 maps · 75%
- Correction of turbo pressure f(IAT)10 maps · 72%
- Slow incremental factor of turbo pressure72%
- Correction of slow incremental factor of turbo pressure71%
- Fast reduction factor of turbo pressure71%
- Limiter of steady turbo pressure6 maps · 68%
- Limiter of Turbo pressure f(IAT)43%
- Correction of turbo pressure36%
- Wastegate Duty Cycle2 maps · 35%
Spark Advance 29 maps
- Spark Advance base map6 maps · 99%
- Spark advance during cranking3 maps · 86%
- Optimal Spark Advance4 maps · 50%
- Limiter of knocking sensor4 maps · 41%
- Minimum Spark Advance12 maps · 41%
Limiters 24 maps
- RPM Limiter13 maps · 99%
- RPM limiter (higher threshold)3 maps · 97%
- Maximum speed of vehicle8 maps · 91%
Injection System 17 maps
- Requested Lambda3 maps · 99%
- Injection correction7 maps · 65%
- Injection enrichment61%
- Lambda for component protection6 maps · 53%
Air Control 14 maps
- Requested engine load99%
- Airflow mass through throttle valve2 maps · 95%
- Threshold of end limitation on throttle valve angle95%
- Throttle valve - operating angle95%
- Throttle valve f(Accelerator pedal)85%
- Exhaust gas temperature3 maps · 64%
- Engine load limiter5 maps · 56%
Variable Valve Timing (VVT) 10 maps
- Intake10 maps · 41%
Rail 7 maps
- Rail pressure5 maps · 67%
- Rail pressure limiter f(RPM,Fuel_Q)51%
- Rail pressure limiter f(RPM,Fuel_T)38%
Deactivations 6 maps
- Lambda Sensor (1=ON, 0=OFF)4 maps · 66%
- Catalytic converter Diagnosis (1=ON, 0=OFF)2 maps · 62%
How this pack differs from other Bosch MED9.1 packs
Named here, but by under half of the 152 Bosch MED9.1 packs:
- Torque request during take off condition 9%
- Wastegate Duty Cycle 35%
- Correction of turbo pressure 36%
- Torque request during standard condition 36%
- Rail pressure limiter f(RPM,Fuel_T) 38%
- Engine torque correction 40%
- Intake 41%
- Limiter of knocking sensor 41%
- Minimum Spark Advance 41%
- Torque request - Low speed 43%
- Limiter of Turbo pressure f(IAT) 43%
- Torque limiter for clutch protection 46%
- Torque monitoring 49%
Named by at least half of them, but not by this pack:
- Injection base map 74%
- Correction of impulsive turbo pressure f(IAT) 65%
- Linearization of impulsive turbo pressure 56%
- Limiter of Turbo pressure f(APS) 53%
- Torque request during take off condition - Fifth Gear 53%
- Torque request during take off condition - First Gear 53%
- Torque request during take off condition - Forth Gear 53%
- Torque request during take off condition - Second Gear 53%
- Torque request during take off condition - Third Gear 53%
- Torque request during take off condition - Reverse Gear 51%
181 maps against the Bosch MED9.1 median
The 152 Bosch MED9.1 packs name 27 to 213 maps, median 94.5; 89% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Engine Torque | 41 | 15 |
| Turbo System | 33 | 20 |
| Spark Advance | 29 | 22 |
| Limiters | 24 | 17 |
| Injection System | 17 | 11 |
| Air Control | 14 | 9 |
| Variable Valve Timing (VVT) | 10 | 0 |
| Rail | 7 | 6 |
| Deactivations | 6 | 2 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.