8V0906264E_0003 Siemens SIMOS12.1 map pack – Seat Leon 1.8 180hp
CAL
8V0906264E_0003Spark Advance75Engine Torque64Air Control21Limiters18Turbo System16Rail8Injection System7
This pack holds 209 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
Seat Leon 1.8 180hp · Siemens SIMOS12.1
More packs: Seat Leon · Siemens SIMOS12.1
All 209 maps
The percentage beside a name: the share of the 14 Siemens SIMOS12.1 packs that name it too.
Spark Advance 75 maps
- Optimal Spark Advance38 maps · 100%
- Spark Advance base map37 maps · 100%
Engine Torque 64 maps
- Limiter of Maximum torque34 maps · 100%
- Optimal engine torque17 maps · 100%
- Torque request during standard condition4 maps · 100%
- Calculated engine torque86%
- Torque request during take off condition - Automatic Transmission6 maps · 86%
- Torque limiter for clutch protection2 maps · 71%
Air Control 21 maps
- Reference of maximum throttle valve angle100%
- Requested engine load16 maps · 100%
- Throttle valve100%
- Engine load limiter2 maps · 93%
- Exhaust gas temperature93%
Limiters 18 maps
- Maximum speed of vehicle8 maps · 100%
- RPM Limiter5 maps · 100%
- RPM limiter (higher threshold)2 maps · 64%
- RPM limiter in Neutral3 maps · 64%
Turbo System 16 maps
- Turbo pressure4 maps · 100%
- Wastegate Duty Cycle4 maps · 100%
- Limiter of Turbo pressure7 maps · 93%
- Limiter of impulsive turbo pressure57%
Rail 8 maps
- Rail pressure8 maps · 93%
Injection System 7 maps
- Injection at full load100%
- Injection base map2 maps · 100%
- Requested Lambda3 maps · 100%
- Lambda for component protection93%
How this pack differs from other Siemens SIMOS12.1 packs
Named by at least half of them, but not by this pack:
- Catalytic converter Diagnosis (1=ON, 0=OFF) 79%
- Torque request during take off condition 64%
- Cylinder head temperature 50%
- Maximum allowable exhaust gas temperature for spark retard control 50%
- Maximum turbocharger temperature 50%
- Minimum Spark Advance 50%
- Threshold for turbocharger speed reduction 50%
209 maps against the Siemens SIMOS12.1 median
The 14 Siemens SIMOS12.1 packs name 80 to 312 maps, median 209; 36% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Spark Advance | 75 | 75 |
| Engine Torque | 64 | 66 |
| Air Control | 21 | 21 |
| Limiters | 18 | 20.5 |
| Turbo System | 16 | 17 |
| Rail | 8 | 8 |
| Injection System | 7 | 7 |
| Deactivations | 0 | 1 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.