−10%10% off all files right now — originals €18, map packs from €54.
€18 / file−10%

8V0906259_0008 Siemens SIMOS12.1 map pack – Audi S3 2.0 280hp

CAL8V0906259_0008
Spark Advance75Engine Torque65Air Control21Turbo System18Limiters13Rail8Injection System7Deactivations2

This pack holds 209 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.

Audi S3 2.0 280hp · Siemens SIMOS12.1

More packs: Audi S3 · Siemens SIMOS12.1

Where do I find these numbers?

All 209 maps

The percentage beside a name: the share of the 14 Siemens SIMOS12.1 packs that name it too.

Spark Advance 75 maps

  • Optimal Spark Advance38 maps · 100%
  • Spark Advance base map37 maps · 100%

Engine Torque 65 maps

  • Limiter of Maximum torque36 maps · 100%
  • Optimal engine torque16 maps · 100%
  • Torque request during standard condition4 maps · 100%
  • Calculated engine torque86%
  • Torque request during take off condition - Automatic Transmission4 maps · 86%
  • Torque limiter for clutch protection71%
  • Torque request during take off condition3 maps · 64%

Air Control 21 maps

  • Reference of maximum throttle valve angle100%
  • Requested engine load16 maps · 100%
  • Throttle valve100%
  • Engine load limiter2 maps · 93%
  • Exhaust gas temperature93%

Turbo System 18 maps

  • Turbo pressure5 maps · 100%
  • Wastegate Duty Cycle4 maps · 100%
  • Limiter of Turbo pressure8 maps · 93%
  • Limiter of impulsive turbo pressure57%

Limiters 13 maps

  • Maximum speed of vehicle8 maps · 100%
  • RPM Limiter5 maps · 100%

Rail 8 maps

  • Rail pressure8 maps · 93%

Injection System 7 maps

  • Injection at full load100%
  • Injection base map2 maps · 100%
  • Requested Lambda3 maps · 100%
  • Lambda for component protection93%

Deactivations 2 maps

  • Catalytic converter Diagnosis (1=ON, 0=OFF)2 maps · 79%

How this pack differs from other Siemens SIMOS12.1 packs

Named by at least half of them, but not by this pack:

  • RPM limiter (higher threshold) 64%
  • RPM limiter in Neutral 64%
  • Cylinder head temperature 50%
  • Maximum allowable exhaust gas temperature for spark retard control 50%
  • Maximum turbocharger temperature 50%
  • Minimum Spark Advance 50%
  • Threshold for turbocharger speed reduction 50%

209 maps against the Siemens SIMOS12.1 median

The 14 Siemens SIMOS12.1 packs name 80 to 312 maps, median 209; 36% of them name fewer than this one.

CategoryThis packMedian pack
Spark Advance7575
Engine Torque6566
Air Control2121
Turbo System1817
Limiters1320.5
Rail88
Injection System77
Deactivations21

Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.

Original ECU file Siemens SIMOS12.1 · 8V0906259_0008
€18
  1. 1 · E-mail
  2. 2 · Card
  3. 3 · File

Checking availability…

All sales are final — no refunds.

Card payment by Stripe · charged only when ready · Terms of sale · Privacy