6579065252 6579065110 Siemens MSD85 map pack – BMW X Series 3.0 306hp
HW
6579065252SW6579065110CAL0049SQ0I610S0VJX7Spark Advance50Engine Torque15Turbo System12Variable Valve Timing (VVT)8Injection System7Limiters6Deactivations3Rail2Air Control1
This pack holds 104 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
BMW X Series 3.0 306hp · Siemens MSD85
More packs: BMW X Series · Siemens MSD85
All 104 maps
The percentage beside a name: the share of the 8 Siemens MSD85 packs that name it too.
Spark Advance 50 maps
- Spark Advance base map20 maps · 100%
- Limiter of knocking sensor8 maps · 62%
- Minimum Spark Advance11 maps · 62%
- Optimal Spark Advance2 maps · 62%
- Spark Advance at full load4 maps · 50%
- Spark advance at low load4 maps · 38%
- Spark Advance at partial load38%
Engine Torque 15 maps
- Optimal engine torque3 maps · 100%
- Calculated engine torque75%
- Limiter of Maximum torque75%
- Torque request during standard condition4 maps · 75%
- Torque request during take off condition3 maps · 75%
- Engine torque correction62%
- Maximum engine torque correction f(ECT_T)62%
- Torque monitoring62%
Turbo System 12 maps
- Limiter of Turbo pressure8 maps · 100%
- Limiter of Turbo pressure f(IAT)2 maps · 62%
- Turbine efficiency62%
- Correction of steady turbo pressure f(IAT)50%
Variable Valve Timing (VVT) 8 maps
- Exhaust4 maps · 75%
- Intake4 maps · 62%
Injection System 7 maps
- Injection base map2 maps · 100%
- Lambda for component protection100%
- Requested Lambda100%
- Injection at full load75%
- Injection correction2 maps · 62%
Limiters 6 maps
- RPM limiter (higher threshold)3 maps · 75%
- RPM Limiter50%
- RPM limiter (lower threshold)2 maps · 25%
Deactivations 3 maps
- Catalytic converter Diagnosis (1=ON, 0=OFF)62%
- Lambda Sensor (1=ON, 0=OFF)2 maps · 62%
Rail 2 maps
- Rail pressure2 maps · 100%
Air Control 1 map
- Airflow mass through throttle valve100%
How this pack differs from other Siemens MSD85 packs
Named here, but by under half of the 8 Siemens MSD85 packs:
- RPM limiter (lower threshold) 25%
- Spark Advance at partial load 38%
- Spark advance at low load 38%
Named by at least half of them, but not by this pack:
- Maximum speed of vehicle 75%
- Exhaust - Temperature correction 50%
- Intake - Temperature correction 50%
- Torque limiter for clutch protection 50%
- Wastegate Duty Cycle 50%
104 maps against the Siemens MSD85 median
The 8 Siemens MSD85 packs name 29 to 116 maps, median 96; 62% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Spark Advance | 50 | 30 |
| Engine Torque | 15 | 19 |
| Turbo System | 12 | 8 |
| Variable Valve Timing (VVT) | 8 | 8 |
| Injection System | 7 | 7 |
| Limiters | 6 | 8 |
| Deactivations | 3 | 2.5 |
| Rail | 2 | 1 |
| Air Control | 1 | 1 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.