0047920I9E1SIG9X3 Siemens MSD85 map pack – BMW 5 Series 4.4 408hp
CAL
0047920I9E1SIG9X3Spark Advance30Engine Torque23Variable Valve Timing (VVT)14Limiters8Turbo System8Injection System7Deactivations4Rail1Air Control1
This pack holds 96 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
BMW 5 Series 4.4 408hp · Siemens MSD85
More packs: BMW 5 Series · Siemens MSD85
All 96 maps
The percentage beside a name: the share of the 8 Siemens MSD85 packs that name it too.
Spark Advance 30 maps
- Spark Advance base map12 maps · 100%
- Limiter of knocking sensor8 maps · 62%
- Minimum Spark Advance10 maps · 62%
Engine Torque 23 maps
- Optimal engine torque3 maps · 100%
- Calculated engine torque75%
- Limiter of Maximum torque75%
- Torque request during standard condition6 maps · 75%
- Torque request during take off condition6 maps · 75%
- Engine torque correction62%
- Maximum engine torque correction f(ECT_T)62%
- Torque monitoring2 maps · 62%
- Torque limiter for clutch protection2 maps · 50%
Variable Valve Timing (VVT) 14 maps
- Exhaust2 maps · 75%
- Intake2 maps · 62%
- Exhaust - Temperature correction5 maps · 50%
- Intake - Temperature correction5 maps · 50%
Limiters 8 maps
- Maximum speed of vehicle2 maps · 75%
- RPM limiter (higher threshold)6 maps · 75%
Turbo System 8 maps
- Limiter of Turbo pressure5 maps · 100%
- Limiter of Turbo pressure f(IAT)62%
- Turbine efficiency62%
- Wastegate Duty Cycle50%
Injection System 7 maps
- Injection base map2 maps · 100%
- Lambda for component protection100%
- Requested Lambda100%
- Injection at full load75%
- Injection correction2 maps · 62%
Deactivations 4 maps
- Lambda Sensor (1=ON, 0=OFF)4 maps · 62%
Rail 1 map
- Rail pressure100%
Air Control 1 map
- Airflow mass through throttle valve100%
How this pack differs from other Siemens MSD85 packs
Named by at least half of them, but not by this pack:
- Catalytic converter Diagnosis (1=ON, 0=OFF) 62%
- Optimal Spark Advance 62%
- Correction of steady turbo pressure f(IAT) 50%
- RPM Limiter 50%
- Spark Advance at full load 50%
96 maps against the Siemens MSD85 median
The 8 Siemens MSD85 packs name 29 to 116 maps, median 96; 38% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Spark Advance | 30 | 30 |
| Engine Torque | 23 | 19 |
| Variable Valve Timing (VVT) | 14 | 8 |
| Limiters | 8 | 8 |
| Turbo System | 8 | 8 |
| Injection System | 7 | 7 |
| Deactivations | 4 | 2.5 |
| Rail | 1 | 1 |
| Air Control | 1 | 1 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.