1037386127 Bosch EDC16C34 map pack – Peugeot 207 1.6 110hp
HW
0281xxxxxxSW1037386127Injection System19Turbo System13Rail12Engine Torque10Air Control6Deactivations3Limiters2
This pack holds 65 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
Peugeot 207 1.6 110hp · Bosch EDC16C34
Also written: 1 037 386 127
More packs: Peugeot 207 · Bosch EDC16C34
All 65 maps
The percentage beside a name: the share of the 252 Bosch EDC16C34 packs that name it too.
Injection System 19 maps
- Fuel quantity injected f(RPM,Trq)5 maps · 100%
- Injection timing - Main Injection Base Map 12 maps · 94%
- Fuel quantity limiter93%
- Injection time83%
- Injection timing - Main Injection Base Map 24 maps · 79%
- Smoke limitation - Lower Lambda value76%
- Injection timing - Main Injection Base Map 33 maps · 58%
- Phase of injection2 maps · 23%
Turbo System 13 maps
- Turbo pressure4 maps · 100%
- Limiter of Turbo pressure2 maps · 96%
- Limiter of Turbo pressure f(APS)78%
- Limiter of Turbo pressure f(IAT)78%
- Variable geometry (VGT) or wastegate (WG) control5 maps · 11%
Rail 12 maps
- Rail pressure4 maps · 100%
- Rail pressure limiter f(RPM,Fuel_Q)3 maps · 100%
- Rail pressure limiter4 maps · 62%
- Rail pressure limiter f(RPM,Fuel_T)30%
Engine Torque 10 maps
- Limiter of Maximum torque2 maps · 100%
- Torque during cranking f(RPM,ECT)95%
- Torque request during standard condition87%
- Torque request during take off condition87%
- Torque request for Sport mode functionality A3 maps · 6%
- Torque request for Sport mode functionality B2 maps · 6%
Air Control 6 maps
- EGR control - Opening percentage2 maps · 28%
- Gas quantity recirculation4 maps · 11%
Deactivations 3 maps
- Speed limiters (switch)3 maps · 40%
Limiters 2 maps
- Maximum speed of vehicle86%
- Idle engine speed f(ECT)56%
How this pack differs from other Bosch EDC16C34 packs
Named here, but by under half of the 252 Bosch EDC16C34 packs:
- Torque request for Sport mode functionality A 6%
- Torque request for Sport mode functionality B 6%
- Gas quantity recirculation 11%
- Variable geometry (VGT) or wastegate (WG) control 11%
- Phase of injection 23%
- EGR control - Opening percentage 28%
- Rail pressure limiter f(RPM,Fuel_T) 30%
- Speed limiters (switch) 40%
Named by at least half of them, but not by this pack:
- Maximum torque for first gear 90%
- Maximum torque for reverse gear 90%
- Maximum torque for fifth gear 89%
- Maximum torque for forth gear 89%
- Maximum torque for second gear 89%
- Maximum torque for third gear 89%
- Variable Geometry Duty Cycle 89%
- Maximum torque for sixth gear 83%
- EGR Valve 62%
- Torque request during take off condition - Reverse Gear 54%
65 maps against the Bosch EDC16C34 median
The 252 Bosch EDC16C34 packs name 27 to 96 maps, median 57; 67% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Injection System | 19 | 18 |
| Turbo System | 13 | 10 |
| Rail | 12 | 7 |
| Engine Torque | 10 | 18 |
| Air Control | 6 | 0 |
| Deactivations | 3 | 2 |
| Limiters | 2 | 2 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.