Bosch MG1CP002 map pack – Mercedes GLE 3.0 367hp
Spark Advance76Engine Torque36Air Control34Injection System32Turbo System22Variable Valve Timing (VVT)20Limiters19
This pack holds 239 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
Mercedes GLE 3.0 367hp · Bosch MG1CP002
More packs: Mercedes GLE · Bosch MG1CP002
All 239 maps
The percentage beside a name: the share of the 13 Bosch MG1CP002 packs that name it too.
Spark Advance 76 maps
- Minimum Spark Advance10 maps · 100%
- Optimal Spark Advance50 maps · 100%
- Spark Advance base map16 maps · 100%
Engine Torque 36 maps
- Limiter of Maximum torque17 maps · 100%
- Optimal engine torque8 maps · 100%
- Torque monitoring9 maps · 100%
- Maximum torque limiter f(EGT)2 maps · 92%
Air Control 34 maps
- Airflow mass through throttle valve100%
- Engine load limiter2 maps · 100%
- Exhaust gas temperature26 maps · 100%
- Requested engine load100%
- Throttle valve2 maps · 100%
- Throttle valve - operating angle100%
- Volumetric efficiency100%
Injection System 32 maps
- Fuel quantity limiter6 maps · 100%
- Injection at full load100%
- Injection correction13 maps · 100%
- Injection enrichment2 maps · 100%
- Lambda for component protection9 maps · 100%
- Requested Lambda100%
Turbo System 22 maps
- Ambient pressure threshold for charge pressure diagnostics100%
- Characteristic widening error threshold due to desired boost pressure dynamics100%
- Compressor efficiency2 maps · 100%
- Delta pressure limit under overcharge error100%
- Deviation negative threshold of boost pressure for detecting overcharge pressure100%
- Limiter of Turbo pressure7 maps · 100%
- Limiter of Turbo pressure f(IAT)2 maps · 100%
- Maximum lower tolerance of pressure before throttle100%
- Turbo pressure4 maps · 100%
- Wastegate Duty Cycle100%
- Lower limit for low pass filtered boost control deviation92%
Variable Valve Timing (VVT) 20 maps
- Intake18 maps · 85%
- Exhaust2 maps · 77%
Limiters 19 maps
- Maximum speed of vehicle2 maps · 100%
- RPM Limiter11 maps · 100%
- RPM limiter (higher threshold)6 maps · 100%
How this pack differs from other Bosch MG1CP002 packs
Named by at least half of them, but not by this pack:
- Debounce time to detect a permanent torque limit 92%
239 maps against the Bosch MG1CP002 median
The 13 Bosch MG1CP002 packs name 202 to 288 maps, median 252; 8% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Spark Advance | 76 | 76 |
| Engine Torque | 36 | 36 |
| Air Control | 34 | 34 |
| Injection System | 32 | 32 |
| Turbo System | 22 | 22 |
| Variable Valve Timing (VVT) | 20 | 35 |
| Limiters | 19 | 18 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.