C1BA-12B684-DA C1BY-12A650-AD Bosch MED17.0.1 map pack – Ford Fiesta 1.6 180hp
C1BA-12B684-DASWC1BY-12A650-ADUPGC1BY-14C204-MAThis pack holds 130 maps of this exact software version, each with its X/Y axes and factor — ready to import into WinOLS. The full list is below.
Ford Fiesta 1.6 180hp · Bosch MED17.0.1
Also written: C1BA 12B684 DA · C1BA12B684DA · C1BY 12A650 AD · C1BY12A650AD · C1BY 14C204 MA · C1BY14C204MA
More packs: Ford Fiesta · Bosch MED17.0.1
All 130 maps
The percentage beside a name: the share of the 22 Bosch MED17.0.1 packs that name it too.
Limiters 44 maps
- RPM Limiter43 maps · 100%
- Maximum speed of vehicle45%
Engine Torque 29 maps
- Optimal engine torque95%
- Maximum torque for fifth gear86%
- Maximum torque for first gear86%
- Maximum torque for forth gear86%
- Maximum torque for reverse gear86%
- Maximum torque for second gear86%
- Maximum torque for sixth gear86%
- Maximum torque for third gear86%
- Torque limiter for clutch protection86%
- Torque request during take off condition - Fifth Gear73%
- Torque request during take off condition - First Gear73%
- Torque request during take off condition - Forth Gear73%
- Torque request during take off condition - Reverse Gear2 maps · 73%
- Torque request during take off condition - Second Gear73%
- Torque request during take off condition - Sixth Gear2 maps · 73%
- Torque request during take off condition - Third Gear73%
- Calculated engine torque68%
- Limiter of Maximum torque6 maps · 64%
- Torque monitoring4 maps · 27%
Turbo System 19 maps
- Limiter of steady turbo pressure86%
- Wastegate Duty Cycle77%
- Limiter of impulsive turbo pressure73%
- Turbo pressure7 maps · 64%
- Limiter of Turbo pressure4 maps · 59%
- Compressor efficiency27%
- Maximum turbocharger speed27%
- Ambient pressure threshold for charge pressure diagnostics14%
- Deviation negative threshold of boost pressure for detecting overcharge pressure14%
- Lower limit for low pass filtered boost control deviation14%
Injection System 13 maps
- Requested Lambda2 maps · 100%
- Injection base map2 maps · 91%
- Lambda for component protection2 maps · 82%
- Injection enrichment77%
- Injection correction f(ECT)6 maps · 64%
Spark Advance 12 maps
- Spark Advance base map91%
- Optimal Spark Advance2 maps · 55%
- Minimum Spark Advance5 maps · 27%
- Limiter of knocking sensor4 maps · 23%
Air Control 10 maps
- Requested engine load100%
- Airflow mass through throttle valve91%
- Engine load limiter82%
- Threshold of end limitation on throttle valve angle82%
- Throttle valve f(Accelerator pedal)73%
- Exhaust gas temperature68%
- Throttle valve - operating angle68%
- Reference of maximum throttle valve angle23%
- Maximum relative air charge for catalyst diagnosis9%
- Minimum relative air charge for catalyst diagnosis9%
Rail 3 maps
- Rail pressure73%
- Rail pressure limiter f(RPM,Fuel_Q)2 maps · 68%
How this pack differs from other Bosch MED17.0.1 packs
Named here, but by under half of the 22 Bosch MED17.0.1 packs:
- Maximum relative air charge for catalyst diagnosis 9%
- Minimum relative air charge for catalyst diagnosis 9%
- Ambient pressure threshold for charge pressure diagnostics 14%
- Deviation negative threshold of boost pressure for detecting overcharge pressure 14%
- Lower limit for low pass filtered boost control deviation 14%
- Limiter of knocking sensor 23%
- Reference of maximum throttle valve angle 23%
- Compressor efficiency 27%
- Maximum turbocharger speed 27%
- Minimum Spark Advance 27%
- Torque monitoring 27%
- Maximum speed of vehicle 45%
Named by at least half of them, but not by this pack:
- RPM limiter (higher threshold) 73%
- Torque request during take off condition 68%
- Exhaust 50%
- Intake 50%
- Optimal Spark Advance 1 50%
- Torque limiter for vehicle speed 50%
130 maps against the Bosch MED17.0.1 median
The 22 Bosch MED17.0.1 packs name 15 to 148 maps, median 89.5; 77% of them name fewer than this one.
| Category | This pack | Median pack |
|---|---|---|
| Limiters | 44 | 13.5 |
| Engine Torque | 29 | 26 |
| Turbo System | 19 | 6 |
| Injection System | 13 | 10 |
| Spark Advance | 12 | 4 |
| Air Control | 10 | 9 |
| Rail | 3 | 3.5 |
| Variable Valve Timing (VVT) | 0 | 4 |
Map definitions only — no tuned values; the pack fits this software version only. Original read only (no full backup or EEPROM). A digital file: all sales are final — no refunds.